Controller Model | WWS06-48 |
Wind Turbine Input |
|
Rated input power |
600W |
Rated input voltage |
56Vdc |
Input voltage range |
0~64Vdc |
Rated input current |
13Adc |
Brake by hand |
Press button "Enter" "Esc" at the same time to unload completely. Then recover by hand. |
Brake by over current |
13A (factory default,0~13A settable) |
Brake by overvoltage |
Refer to "output overvoltage" control |
Brake by over wind speed (optional) |
14m/s (0-30m/s settable) |
Brake by over rotational Speed (optional) |
500 r/min (factory default,0~1000r/min settable) |
PV Input Parameters |
|
Rated input power |
300W |
Max. open circuit voltage |
96V |
Rated input current |
7A |
Reversed connection protection |
YES |
Charge Parameters |
|
Rated battery voltage |
48V |
Temperature compensation function (optional) |
-3mV/℃/2V |
Output Parameters |
|
Rated output voltage |
48V |
Output overvoltage point |
58V (factory default,44Vdc~64Vdc settable) |
Output overvoltage recovery point |
52.8V (factory default, reduce 5.2V from the output overvoltage point) |
Max. Output current |
13A |
DC Load Output(Optional) |
|
Output loops |
2 loops |
Output control mode |
Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. |
Output voltage range |
43.2V~64V |
Undervoltage recovery point |
Refer to "rated battery voltage" |
Rated output current |
10A/each loop |
Overload protection |
120% rated DC output -1min,150% rated DC output -10s |
Short circuit protection |
200% rated DC output, instant protection |
Rectifier mode |
Uncontrolled rectifier |
Display mode |
LCD |
Display information |
Battery voltage, wind turbine voltage/current/ power, PV power/ voltage/current, light control-on voltage, light control-off voltage, time control duration, load current and so on. |
Monitoring mode (optional) |
RS232/ RS485/ RJ45/ GPRS/ Bluetooth/ Zigbee |
Monitoring Contents |
Real-time display: Battery voltage, wind turbine voltage/current/power, PV power/voltage/current, wind power generation capacity, solar power generation capacity, Battery status, wind turbine status, day and night, DC overload, DC load short circuit, and so on.
---------------
Parameter setting:Output over voltage point, wind turbine over current point, wind turbine start voltage, DC load over voltage/ under voltage/under voltage recovery point, output mode choice for two loops, light control on voltage, light control off voltage, and wind turbine brake settings.
|
Lightning protection |
YES |
Conversion efficiency |
≥95% |
Static loss |
<0.5W |
Environment temperature |
-20℃~+40℃ |
Humidity |
5%~95%,No condensing |
Noise |
≤65dB |
Cooling mode |
Natural cooling |
Installation mode |
Wall-mounted |
Cover protection class |
IP52 |
Product dimension (W*H*D) |
150×205×82mm |
Product net weight |
2.8kg |